Leakage test process

This is leakage test process of AMR case,a Japanese related product.The material is ADC12,NC machining after electrophoresis treatment.The dimension and surface requirements are both very high. Air pressure:0.1Mpa Clamping time:25 seconds Setting time:13 seconds Checking time:2 seconds Standard value :0.4ml/min